ALLER AIR ANALYSIS

I have received the unit that was purchased from the open market and was very disappointed in it. I wonder how this unit can be developed, for our market; again this should not be our competition!

The comparison is listed below:

 
Aller Air
Care 2000
Total unit weight in pounds
44
50
Unit size in inches
20.5 x 15.25 dia
29 x 14 x 15
HEPA filter square foot
28
80
Filter monitoring
none
pressure guage
UVGI monitoring
none
LED light
Carbon weight in pounds
13
15
Noise level in decibels
95 high
55 high
 
58 low
43 low
UVGI lamp wattage
1 @ 10 w
2 @ 9 w
Lamp germicidal irradiation
30 m w-s/cm2
64 m w-s/cm2 with 2 lamps
UV effective chamber size
15" dia x 3" high
14" x 15" x 10"

Micro watt sec/cm squared of effective irradiation power used for killing airborne pathogens

741
12,456

This unit has a small 6" long, 10-watt UV lamp. It is mounted in a chamber that is shared by the motor and the motor housing shadows half the chamber. Therefore, the effective UV is reduced because of this shadowing. The calculation takes this shadowing and the reflectivity of the chamber into account. Also, the air passages to get to the UV from the HEPA filter are less than 3/8" and the chamber is only 3" high, meaning the air velocity through the chamber is a very high 7 feet per second at the 320 cfm airflow. Therefore, the residence time for the UV to act on the pathogens would be less than a tenth of a second. The irradiation power even at low speed would still only be 4,742 m w-s/cm2. The CARE would be 43,600 m w-s/cm2 at low speed.

The airflow pattern set up with the supply air out the side is poor. When on low speed, short cycling of clean air is prevalent. Clean air must be directed into the breathing zone. This way people are breathing the cleanest air possible, all the time.

The airflow rate is listed at 400cfm. The measured airflow is actually 320 cfm. This speed is noted as turbo and does indeed sound like a "turbo" / jet engine. The unit would not typically be used on high speed because of the noise; one actually could not carry on a conversation. Medium speed is much lower at 100 cfm.

The "whisper" setting the manufacturer states is for night time/sleep and is so low that no real, effective air changes are made and at minimal air cleaning. CFM is tested at 52 cfm.

Filter changing is not indicated with any type of monitor. The CARE is by actual pressure drop across the filter.

The mfg advertises a sophisticated, high efficiency motor, which is really a standard everyday 3-speed type.

This unit seems to have been developed for connection onto a ducted HVAC system. The bright yellow school bus color may be nice in the basement but doubtful it being used in a living room, or NYC office