PARTICLE
AND SPORE TEST FOR CLARIFIER
ABSTRACT - The purpose
of the test was to set up a closed system that best simulated a standard
residential room. The particle counts in the test chamber would also be
able to be identified and counted in a controlled scientific manner. The
results tabulated and a realistic conclusion made.
PROCEDURE - A dust
tight room was built with clear poly sheets mounted on all six sides onto
a frame with seams carefully taped with packaging tape.
*The air sampling
was performed on the outside and inside of the air chamber.
*The air sampling was then started immediately after placing the unit
inside the chamber after taping all extra seams and running it on
medium fan speed.
*Samples were obtained from factory supplied, 15 liters per minute
vacuum pump, and each sample was run for a 10-minute collection time.
*Ambient temperature was 68 degrees F and humidity level was 50%.
*The chamber was 8 ft x 8 ft x 10 ft high.
*This chamber was sealed on all seams with plastic packaging tape.
New dust free materials were used in the construction.
*Collection site was at 6 feet above floor inside the chamber and
16 inches in from the front and 12 inches in from the sidewall. The
outside chamber collection site was 24 inches out from chamber walls
and 5 feet above the floor. See sketch below.
*Unit was placed on the floor at the center part of the rear wall
at 3" from the rear wall surface. See sketch below.
*See actual spore count sample test sheet attached, which lists the
actual spores that were included in test.
SPORE
CHAMBER DESIGN FOR AIR CLEANING TEST
LAB
TESTING
Project
# 04009-010AA
Air Quality Sciences, Inc.
Marietta, GA.
Air - O - Cell Spore Trap Sampling
Sample Times for spore test
Sampling date - 5 / 18 / 98
| TEST # |
TIME and LOCATION |
ACTUAL COUNT |
| ST 1 |
test start, outside
chamber |
95 |
| ST 2 |
test start, inside
chamber |
51 |
| ST 3 |
+ 1 hour from
test start, inside chamber |
0 |
| ST 4 |
+ 2 hour from
test start, inside chamber |
0 |
| ST 5 |
+ 3 hour from
test start, inside chamber |
2 |
| ST 6 |
+ 3 hour from
test start, outside chamber |
105 |
| ST 7 |
+ 4 hour from
test start, inside chamber |
0 |
| ST 8 |
+ 5 hour from
test start, inside chamber |
0 |
| ST 9 |
+ 23 hours from
test start, inside chamber |
0 |
| ST 10 |
+ 23 hours from
test start, outside chamber |
72 |
Samples were collected
and sealed with factory-supplied tape. All samples were previously numbered,
placed into a box and sent to the lab for the actual spore counting. See
attached sample test log sheet for the type of spores tested and cataloging.
RESULTS - Attached
is the graph of the data results, which shows the rapid resultant reduction
in room spore counts.
CONCLUSION - The test
showed the ability to simulate a home environment and successfully reduce
and maintain, over time, a very low level of particulate mater in the
space. Test result show the air cleaning unit was very successful in reducing
the fungal spores in the air of the test chamber and the results can be
directly related to the ability of the unit to clean the air in any room,
either in a residence or an office complex.